Pioneer Blade is the most energy efficient≈ wall mounted split system air conditioning in Australia. All of the benefits of Pioneer Pro in a wall-mounted system make Pioneer Blade an inexpensive way to cool and heat a single room or space.
| MODEL | GR-036-A6 | GR-063-A6 | GR-080-A6 | ||
|---|---|---|---|---|---|
| Function | - | - | - | - | - |
| Capacity | Cool | W | 3850 | 6930 | 8800 |
| Heat | W | 4230 | 6930 | 9240 | |
| AEER | - | W/W | 4.83 | 4.47 | 4.46 |
| Star Rating | (AEER) | - | 5.0 | 4.0 | 4.0 |
| ACOP | - | W/W | 4.86 | 4.47 | 4.52 |
| Star Rating | (ACOP) | - | 5.0 | 4.0 | 4.5 |
| Power Supply | - | Ph,V,Hz | 1,240,50 | 1,240,50 | 1,240,50 |
| Power Input | Cool | W | 796 | 1550 | 1970 |
| Heat | W | 870 | 1550 | 2040 | |
| Rated Current | Cool | A | 7.3 | 9.6 | 13 |
| Heat | A | 7.3 | 9.6 | 13 | |
| Air Volume | - | m3/h | 600 | 950 | 1200 |
| Indoor Unit | GR-036-A6 | GR-063-A6 | GR-080-A6 | ||
|---|---|---|---|---|---|
| Sound Pressure Level | SH/H/M/L | DB(A) | 42/39/36/33 | 49/45/41/37 | 51/48/42/39 |
| Net Dimensions | WxHxD | mm | 845x275x180 | 1007x315x219 | 1178x326x253 |
| Gross dimensions | WxHxD | mm | 918x370x258 | 1076x398x328 | 1268x420x348 |
| Weight | Net/Gross | kg | 11/14 | 16/21 | 17.5/23.5 |
| Outdoor Unit | GR-036-A6 | GR-063-A6 | GR-080-A6 | ||
|---|---|---|---|---|---|
| Sound Pressure Level | - | DB(A) | 50 | 47/52 | 49/54 |
| Pipe Connection | Gas | mm | Ø9.52 | Ø16 | Ø16 |
| - | Liquid | mm | Ø6 | Ø6 | Ø6 |
| Refrigerant | - | - | PI60 | PI60 | PI60 |
| Refrigerant Charge | - | kg | 0.65 | 0.98 | 0.99 |
| Net Dimensions | WxHxD | mm | 845x275x180 | 955x700x396 | 980x790x427 |
| Gross dimensions | WxHxD | mm | 918x370x258 | 1029x750x458 | 1083x855x488 |
| Weight | Net/Gross | kg | 36/39 | 50/55 | 70/75 |
Pioneer RENEW enables you to rebuild your existing ducted air conditioning system so that you save money and enjoy the same excellence in engineering.
“Rebuilding” means we replace the outside unit so that it runs on M60 refrigerant with all the benefits made available in the Pioneer Pro: lower operating cost, better environmental impact and the safety of a natural refrigerant. We make minor adjustments to the indoor unit.
The result – quick replacement of your existing system and less disruption to your home or business. Better still you save money by avoiding the need to install an entirely new system and you get a far more energy efficient≈ air conditioning system.
Pioneer RENEW will deliver far greater energy efficiency than your existing split system because of the revolutionary performance of M60.
Better still you are using state of the art technology that is both safer and more efficient.
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Power Supply V-PH- Hz | 240-1-50 | 240-1-50 | 415-3-50 | 240-1-50 |
| Rated Capacity kW | 10 | 14 | 17 | 20 |
| Capacity Range kW | 3.5 -11.5 | 4.9 - 14.1 | 4.0 - 17.5 | 7.0 - 23.0 |
| Rated Input W | 2.18 (0.97-2.93) | 3.04 (1.13-3.74) | 3.70 (1.17-4.47) | 4.5 (2-5.9) |
| Rated Current A | 20.1 | 30.1 | 17.4 | 2 x (20.5) |
| EER W/W | 4.58 | 4.6 | 4.59 | 4.44 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Rated Capacity kW | 11.5 | 16.5 | 18 | 23 |
| Capacity Range kW | 3.8 - 12.8 | 5.3 - 18.3/td> | 5.0 - 18.8 | 7.6 - 25.6 |
| Rated Input W | 2.54 (0.99-2.94) | 3.6 (1.16-4.27) | 3.98 (1.12-4.37) | 5.15 (2-5.98) |
| COP W/W | 4.52 | 4.58 | 4.52 | 4.46 |
| Compressor Type | Rotary | Rotary | Rotary | Rotary |
| Refrigerant Type/Quantity | PI60/1.9kg | PI60/2.15kg | PI60/2.75kg | PI60/2.75kg |
| Refrigerant Pipe Size mm | 3/8 x 5/8 | 3/8 x 5/8 | 3/8 x 3/4 | 1/2 x 3/4 |
| Metering Device | EXV | EXV | EXV | EXV |
| Outdoor Noise Level db(a)Sound Pressure/Sound Power db(a) | 49/52 | 50/53 | 52/55 | 54/56 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Dimensions (WxHxD) mm | 1226x775x290 | 1226x815x330 | 1463x799x389 | 1438x646x475 |
| Packing (WxHxD) mm | 1338x877x305 | 1338x925x345 | 1543x883x470 | - |
| Net / Gross Weight kg | 57/67 | 64/73 | 87/115 | 78 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Dimensions (WxHxD) mm | 1107x440x1100 | 1085x427x1365/td> | 1085x427x1365 | 2 x (1107x440x1100) |
| Packing (WxHxD) mm | 1158x493x1235 | 1148x478x1505 | 1143x478x1505 | 2 x (1158x493x1235) |
| Net / Gross Weight kg | 90/101 | 116/128 | 121/133 | 2 x (90/101) |
The Pioneer Pro employs inverter technology for maximum efficiency and comfort. State of the art technology with an important difference – M60 refrigerant!
M60 is a natural refrigerant that makes the Pioneer PRO the most efficient≈ split system on the market. Your energy savings will be as much as 38% compared to the leading brands of imported air conditioning systems that use synthetic refrigerants.
But we make it better with a seven-year warranty and optional air purification. Pioneer is an Australian owned company that has been manufacturing cooling and heating products for over 30 years. We were the first to offer air purification for those that need to take extra care and we stand behind our products with the leading warranty on the market.
PVAV (Pioneer International Variable Air Volume) option available. Individual zoning control lets you create temperature settings in up to 14 different areas of your home.
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Power Supply V-PH- Hz | 240-1-50 | 240-1-50 | 415-3-50 | 240-1-50 |
| Rated Capacity kW | 10 | 14 | 17 | 20 |
| Capacity Range kW | 3.5 -11.5 | 4.9 - 14.1 | 4.0 - 17.5 | 7.0 - 23.0 |
| Rated Input W | 2.18 (0.97-2.93) | 3.04 (1.13-3.74) | 3.70 (1.17-4.47) | 4.5 (2-5.9) |
| Rated Current A | 20.1 | 30.1 | 17.4 | 2 x (20.5) |
| EER W/W | 4.58 | 4.6 | 4.59 | 4.44 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Rated Capacity kW | 11.5 | 16.5 | 18 | 23 |
| Capacity Range kW | 3.8 - 12.8 | 5.3 - 18.3/td> | 5.0 - 18.8 | 7.6 - 25.6 |
| Rated Input W | 2.54 (0.99-2.94) | 3.6 (1.16-4.27) | 3.98 (1.12-4.37) | 5.15 (2-5.98) |
| COP W/W | 4.52 | 4.58 | 4.52 | 4.46 |
| Compressor Type | Rotary | Rotary | Rotary | Rotary |
| Refrigerant Type/Quantity | PI60/1.9kg | PI60/2.15kg | PI60/2.75kg | PI60/2.75kg |
| Refrigerant Pipe Size mm | 3/8 x 5/8 | 3/8 x 5/8 | 3/8 x 3/4 | 1/2 x 3/4 |
| Metering Device | EXV | EXV | EXV | EXV |
| Outdoor Noise Level db(a)Sound Pressure/Sound Power db(a) | 49/52 | 50/53 | 52/55 | 54/56 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Dimensions (WxHxD) mm | 1226x775x290 | 1226x815x330 | 1463x799x389 | 1438x646x475 |
| Packing (WxHxD) mm | 1338x877x305 | 1338x925x345 | 1543x883x470 | - |
| Net / Gross Weight kg | 57/67 | 64/73 | 87/115 | 78 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Dimensions (WxHxD) mm | 1107x440x1100 | 1085x427x1365/td> | 1085x427x1365 | 2 x (1107x440x1100) |
| Packing (WxHxD) mm | 1158x493x1235 | 1148x478x1505 | 1143x478x1505 | 2 x (1158x493x1235) |
| Net / Gross Weight kg | 90/101 | 116/128 | 121/133 | 2 x (90/101) |
| Model Name | SCVH24A-A1NA | SCVH36A-A1NA | SCVH42A-E1NA | SCVH48A-E1NA |
|---|---|---|---|---|
| Cooling(BTU/h) | 24000 | 36000 | 42000 | 48000 |
| Heating(BTU/h | 26500 | 40000 | 46500 | 53000 |
| Capacity Range(Cooling) | 4800~28800 | 7200~43200 | 8400~50400 | 9600~57600 |
| Capacity Range(Heating) | 5300~31800 | 8000~48000 | 9300~55800 | 10600~13600 |
| Model Name | SCVH24A-A1NA | SCVH36A-A1NA | SCVH42A-E1NA | SCVH48A-E1NA |
|---|---|---|---|---|
| Power Supply (Ph, VHz) | 1ph,220V-240V ,50Hz | 1ph,220V-240V ,50Hz | 3ph,380V-415V ,50Hz | 3ph,380V-415V ,50Hz |
| Power Input (Cooling W) | 2000 | 3100 | 3700 | 4200 |
| Power Input (Heating W) | 2100 | 3150 | 3750 | 4250 |
| Rated Current (Cooling W) | 9.09 | 14.09 | 9.74 | 11.05 |
| Rated Current (Heating W) | 9.55 | 14.32 | 9.87 | 11.18 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Airflow Volume (m3/h) | 1200 | 1600 | 2000 | 2000 |
| Sound Pressure Level (dB(A)(H/L)) | 37/32 | 39/34 | 42/37 | 42/37 |
| Outline Dimension (mm) | 840x840x225 | 840x840x225 | 840x840x300 | 840x840x300 |
| Package Dimension (mm) | 950x950x345 | 950x950x345 | 950x950x420 | 950x950x420 |
| Net Weight/Gross Weight (kg) | 30/35 | 30/35 | 35/41 | 35/41 |
| MODEL | GTIO-100A6 | GTIO-140A6 | GTIO-160A6 | GTIO-200A6 |
|---|---|---|---|---|
| Sound Pressure Level (dB(A) | 55 | 58 | 59 | 60 |
| Piping Connection (Gas/mm) | φ16 | φ16 | φ19 | φ19 |
| Piping Connection (Liquid/mm) | φ6 | φ9.52 | φ9.52 | φ9.25 |
| Outline Dimension (mm) | 890x700x340 | 1020x1000 x396 | 1020x1000 x396 | 1020x1350 x396 |
| Package Dimension (mm) | 1014x763x455 | 1101x1130x448 | 1101x1130x448 | 1101x1480x448 |
| Net Weight/Gross Weight (kg) | 46/50.5 | 75/83 | 110/120 | 110/120 |